Weber TT is a cement-based leveling compound for dry, damp, and wet areas, heated surfaces, and cold conditions. It is suitable for the initial leveling of stone walls, for leveling and renovating old plaster surfaces, and for plastering heated surfaces (firewalls, chimney flues). A single layer can be applied in a thickness of 2–10 mm. The compound is heat- and water-resistant.
• Coverage: approx. 1.4 kg/m²/1 mm
• Application temperature: at least +10°C
• Shelf life: 12 months (in dry conditions, in unopened original packaging)
• Drying time (touch-dry): 1–2 days, depending on layer thickness, temperature, and ventilation
• Mix thickness: 2–10 mm for full leveling; partial leveling up to 30 mm
• Water content during mixing: 6–7 L/25 kg
• Compressive strength at 28 days: >6 MPa (EN 1015-11)
• Binder: cement
• Aggregate: sand, particle size < 1 mm
• Pot life: 4 hours after adding water
• Color: gray
Surface preparation: The substrate must be clean, solid, and free of dust. The substrate must be cleaned of substances that impair adhesion, such as paint, grease, and dust; non-moisture-resistant fillers must also be removed. NOTE! Not suitable for lime plaster. Windows and other surfaces that are not to be leveled must be carefully covered.
Mixing: Use only clean water at room temperature for mixing. Water consumption: 6–7 liters per 25 kg. Mix twice with a mixer attachment—the first mix is done with less water, and the mixture is allowed to stand for about 15 minutes. Mix lightly a second time and add the remaining water. The leveling compound is usable for up to 4 hours after adding water. The temperature of the prepared mixture must exceed +10°C.
Surface Leveling: A wide (60–80 cm) steel trowel is used for surface leveling. The mixture is placed on the steel trowel and applied to the wall in a 3–5 mm thick layer, vertically from the bottom upward. Excess mixture is removed from the steel trowel into the mixing bucket and reused later. For mechanical leveling, the mixture is sprayed onto the wall in an even layer; final leveling is performed manually by smoothing the surface with a steel trowel. Before applying the next layer, the previous layer must be completely dry (1–2 days). In dry conditions, the surface must be moistened afterward.
Safety Precautions: Causes irritation. Contains more than 5% cement by total volume. Avoid inhaling dust and contact with eyes. Irritates the eyes, respiratory tract, and skin. If the mixture comes into contact with the eyes, rinse immediately with water and seek medical attention if necessary. If necessary, wear safety goggles, a respirator, gloves, or protective cream.