Vivacolor J is a water-based, ready-to-use joint filler for dry indoor areas. It is suitable for filling plaster, concrete, brick, and drywall surfaces, as well as for filling joints, cracks, and holes. It offers excellent adhesion and elasticity. The filler is easy to apply and level.
• Binder: acrylic copolymer
• Filler: dolomite
• Particle size: max 0.1 mm
• Layer thickness: max 2 mm
• Adhesion: 1.30 N/mm²
• Color: gray
• Coverage (single coat): ~1 l/m² when applying a 1 mm-thick layer to the surface; ~0.2 l/m² when applying two coats to drywall joints and screw heads.
• Application method: with a putty knife or putty gun.
• Drying time: 1 mm in 2–3 hours (+23 °C, 50% RH). Drying time increases at lower air temperatures and higher humidity.
• Cleaning of tools, thinner: water
• Storage: protect from cold
• Shelf life: 2 years from the date of manufacture in tightly sealed original packaging (see packaging)
Surface preparation: The surface to be filled must be clean and dry, with an air temperature above +5 °C and relative humidity below 80%. Avoid drafts and high temperatures during application.
Unpainted surfaces: Clean the surface of dust and dirt. Wash soiled or previously painted surfaces with Special Clean, rinse, and allow to dry. Prime weak and dusty surfaces with Special Primer alkyd primer.
Previously painted surface: Clean the surface of old, flaking paint, dust, and dirt. Wash dirty or previously painted surfaces with Special Clean, rinse, and let dry. Sand glossy surfaces to a matte finish, then remove sanding dust. Prime weak and dusty surfaces with Special Primer alkyd primer.
Filling: Apply filler using a filler gun or putty knife. Reinforce joints and cracks beforehand with paper or fiberglass tape. If necessary, sand the dried putty surface and remove sanding dust. Protect your eyes and respiratory tract from dust while sanding. Apply a second coat if necessary. Before washing, remove excess putty from tools and wash them with water.
Waste Management, Environmental Protection, and Occupational Safety: The operator must dispose of waste in accordance with local waste management regulations. Do not pour paint products into the sewer system, onto the ground, or into bodies of water. Recycle clean, dry containers; dispose of liquid residues at a hazardous chemical collection point.