The Alfa Term 20 is a wood-fired central heating stove with a water jacket, cooktop, and oven, designed for use in hydronic heating systems, for space heating, and for cooking and baking.
The stove’s handedness is determined by looking at the front: on a right-handed stove, the oven and chimney connection are on the right and the firebox on the left; on a left-handed stove, the layout is reversed.
Rated power: 23.5 kW
Water jacket heat output: 15.0 kW
Room heat output: 8.5 kW
Efficiency: 76%
Energy class / EEI: A / 101
Seasonal energy efficiency: 67%
Dimensions L x W x H: 900 x 600 x 850 mm
Cooking oven dimensions L x W x H: 460 x 440 x 260 mm
Net weight: 164 kg
Water jacket capacity: 14 L
Flue connection: Ø150 mm
Minimum chimney draft: 17 Pa
Flue gas temperature: 223 °C
Flue gas outlet temperature: 268 °C
Flue gas mass flow: 29.8 g/s
Fuel: dry, unprocessed firewood
Operation: with closed firebox door; intermittent firing
. The unit complies with the requirements of EN 16510. Emissions at 13% O₂: CO 1,461 mg/Nm³, PM 32 mg/Nm³, OGC 24 mg/Nm³, NOx 158 mg/Nm³.
Safety clearances from combustible materials: 300 mm to the rear; 400 mm to the sides; 1,500 mm to the front; 1,500 mm in the lateral radiation zone; more than 750 mm upward. Install on a non-combustible base. If the floor is made of combustible material, the manufacturer’s instruction manual requires a metal floor guard that extends at least 500 mm in front of the stove and 100 mm to the sides of the stove. Also comply with any stricter local requirements.
The installer is responsible for proper installation and connection. Have a qualified specialist assess the chimney’s suitability and draft. The connection to the heating system and the overheating protection solution must be designed by a qualified specialist according to the specific model of the appliance. The stove must not be operated without water in the water jacket or without a properly connected heating system. The enclosed instructions apply to the cooling-air model; in a closed system, an external thermal drain and fill valve is required. Follow the instructions on the appliance’s nameplate and comply with local regulations.
Connecting the stove to a masonry chimney requires consultation with a specialist and may only be done at the consumer’s own risk.